Fees
Outside customers please contact PAMS about your project before sending samples. Click the link to download the submission form.
Service | Instrument | UGA and State of Georgia Cost* | Outside Cost | General Descriptions |
---|---|---|---|---|
LC-MS or MS/MS | Bruker Impact II, high res | $50 / LC run / polarity | $65 / LC run / polarity | Liquid chromatography - mass spectrometry using high resolution and mass accurate Q-TOF instrument. Expect 5 PPM or better accuracy and 20k+ resolution |
Ultra High Res. ESI | Bruker SolariX XR 12T FTICR | $45 / sample / polarity | $55 / sample / polarity | Electrospray mass spectrometry using a high resolution and mass accurate FTMS instrument. Better than 1 ppm accuracy and up to a million resolution |
High Res ESI | Bruker Impact II, high res | $35 / sample/polarity | $45/sample/polarity | Electrospray mass spectrometry using a high resolution and mass accurate Q-TOF instrument. Expect 5 PPM or better accuracy and 20k+ resolution |
Low Resolution ESI | Bruker 3000+ ion trap | $20 / sample | $35 / sample | Electrospray mass spectrometry. Produces MH+ and multiply charged ions. Analysis using a low resolution instrument with typical accuracy 0.2 Da. |
Low Resolution ESI by Customer Off Time | Bruker 3000+ ion trap | $15 / sample | N/A | User has been trained and can run own sample on Bruker Esquire 3000 plus instrument. |
MALDI | Bruker Autoflex maX | $15 / sample | $30 / sample | Matrix assisted laser desorption mass spectrometry using on a TOF mass spectrometer. |
MALDI High Res | Bruker SolariX XR 12T FTICR | $45 / sample / polarity | $55 / sample / polarity | Matrix assisted laser desorption mass spectrometry using a high resolution, mass accurate FTICR-MS instrument. Up to a million resolution if required. |
MALDI with quick desalting step | Bruker Autoflex maX | $25 / sample | $50 / sample | Matrix assisted laser desorption mass spectrometry using on a TOF mass spectrometer. |
MALDI Imaging | Bruker SolariX XR 12T FTICR | $100 / hr | $200 / hr | Sample imaging using MALDI on the SolariX FTICR mass spectrometer. |
Protein ID by Peptide Mass Fingerprinting includes In-gel digestion, MALDI-MS and database search | Bruker Autoflex maX | $40 / sample | $50 / sample | Gel band is digested with trypsin. The tryptic fragments are extracted and analyzed by MALDI. The data is then searched against a database for protein ID. Good for bands containing 1 protein. |
LC-MS/MS instrument usage where client helps set up, brings own column and run samples and client does all post analysis | ThermoScientific Orbitrap Velo Elite | $60 / hour | N/A | Nano flow liquid chromatography - mass spectrometry using a high resolution/mass accurate orbitrap instrument. Expect better than 2 PPM accuracy and resolutions up to 120K/15K for MS and MS2, respectively. |
Protein ID by LC-MS/MS-60 minute run. Tryptic peptides readily for analysis and one database search. | ThermoScientific Orbitrap Velo Elite | $90 / sample | $140 / sample | A digest the customer has performed and is ready for analysis by LC-MS/MS on the Orbitrap mass spectrometer coupled with nano-HPLC using a 60 minute elution gradient. The data is searched against a database for protein ID. Excellent for mixtures, such as pulldowns, interacting protein complexes, etc. |
Protein ID by LC-MS/MS-90 minute run. Tryptic peptides readily for analysis and one database search. | ThermoScientific Orbitrap Velo Elite | $115 / sample | $165 / sample | A digest the customer has performed and is ready for analysis by LC-MS/MS on the Orbitrap mass spectrometer coupled with nano-HPLC using a 90 minute elution gradient. The data is searched against a database for protein ID. Good for more complicate samples that require more indepth analyses. |
Protein ID by LC-MS/MS-60 minute run. Includes trypsin digestion, LC-MS/MS, and a database search. | ThermoScientific Orbitrap Velo Elite | $105 / sample | $175 / sample | Proteins in solution or in gel band are digested by PAMS facility. The digest is analyzed using LC-MS/MS on the Orbitrap mass spectrometer coupled with nano-HPLC using a 60 minute elution gradient. The data is then searched against a database for protein ID. Excellent for mixtures, such as pulldowns, interacting protein complexes, etc. |
Protein ID by LC-MS/MS-90 minute run. Includes In-gel digestion, LC-MS/MS, and a database search. | ThermoScientific Orbitrap Velo Elite | $130 / sample | $200 / sample | Proteins in solution or in gel band are digested by PAMS facility. The digest is analyzed using LC-MS/MS on the Orbitrap mass spectrometer coupled with nano-HPLC using a 90 minute elution gradient. The data is then searched against a database for protein ID. Good for more complicate samples that require more indepth analyses. |
*Analysis time after first ½ hour of analysis of astrixed services. Customers will be advised if their request for analysis starts to accrue this additional costs. | $50 / hr | $100 / hour | ||